Loading...

CATEGORIES
UPS MAINTAINER AT-UPS1500-LED 1500 VA EAST
UPS MAINTAINER AT-UPS1500-LED 1500 VA EAST
UPS MAINTAINER AT-UPS1500-LED 1500 VA EAST
UPS MAINTAINER AT-UPS1500-LED 1500 VA EAST
UPS MAINTAINER AT-UPS1500-LED 1500 VA EAST

The product's shade and actual color may differ from what is shown in the picture, as the images are for illustrative purposes. The product description is general and may not include all the product's features.

UPS MAINTAINER AT-UPS1500-LED 1500 VA EAST

269,01 €
Monthly payment from 7.83
3711728

AT-UPS1500-LED

5904194150723

Shipping 2-5 b.d.

Pay 5x53.80€
Quantity
You are interested in this product?
(Read terms of service)

The UPS AT-UPS1500-LED is equipped with a multitude of advanced technologies ensuring active monitoring of the power supply network.

The power supply constantly analyzes voltage, frequency, and phase shift angle, as well as filters the voltage delivered to connected devices. When a network failure is detected, the power supply immediately switches to autonomous operation mode and continues to power the equipment using energy stored in internal batteries.

The device collaborates with power supplies that have active PFC (APFC).

Active power : 900 W
Apparent power : 1500 VA
Input voltage : 230 V AC ± 25 %
Input frequency : 50 / 60 Hz (automatic detection)
Output voltage : 230 V AC ± 10 % (approximated sine wave)
Output frequency : 50 / 60 Hz ± 1 %
Voltage regulation : -
Frequency regulation : -
Switching time : 2 ... 7 ms (typical), max. 10 ms
Charging duration (up to 90% level) : 6 ... 8 hours
Battery : 2 pcs. - 12V/8Ah
Estimated battery runtime : 35 minutes @ 100 W,
17.5 minutes @ 200 W,
11.5 minutes @ 300 W,
4 minutes @ 500 W,
1.5 minutes @ 800 W
Number of outputs : 3 pcs. CEE 7/3 (Schuko)
Management software : UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)
Protection features : Fuse
Short circuit protection
Overload protection
Overvoltage protection - RJ45
Overcurrent protection
Discharge protection
Input voltage filtering
EMI/RFI filter
Operating status indication : LED indicators,
Audible alarm
Main features : Excellent microprocessor control ensuring high reliability
COLD START function for manual battery activation
Automatic AVR voltage regulator
Automatic battery charging in off mode
Self-diagnostic function
2 x RJ45 - Input / Output
USB 2.0 port - Access from PC computer
Remote control - UPSmart application (included)
Customizable alarm
Built-in EMI, RFI filter
The device collaborates with power supplies that have active PFC (APFC)
Purpose : network, servers, workstations
monitoring systems
smaller servers, recorders, telecommunications equipment, VoIP equipment, desktop computers, etc.
Case type : Tower
Operating temperature / relative humidity : 0 °C ... 40 °C / 20 ... 90 %
Weight : 9.55 kg
Dimensions : 348 x 140 x 173 mm
Manufacturer / Brand : EAST
Warranty : 2 years

Instruction EN

UPSmart software manual EN

30 other products in the same category: